Key takeaways
- Federal limits set the floor: 1.6 gallons per flush for toilets, with 2.5 gpm showerheads and 2.2 gpm bathroom faucets as the standard flows EPA compares against.
- WaterSense is a voluntary label for products that use at least 20% less water, with ceilings of 1.28 gpf, 2.0 gpm and 1.5 gpm for those three fixtures.
- Some states and cities require tighter limits than federal law, so the local code, not the product box, decides what you may install.
- Selling the label works best as a household water story: toilets alone are nearly 30% of indoor use.
Three layers of rules, in the order they bite
Fixture efficiency in the US comes in three layers. Federal law sets maximum flows that every new toilet, showerhead and faucet sold must meet. Some states and cities then set tighter limits for products sold or installed within their borders. On top of both sits WaterSense, an EPA label that is voluntary for manufacturers and customers, but often written into rebate programs, green building specs and public bids.
A plumber needs to know all three because they answer different questions. Federal limits tell you what a manufacturer may sell. State and local code tells you what you may install on a permitted job. The label tells you what a utility will rebate and what a spec writer will accept.
The numbers that matter on the truck
WaterSense toilets use 1.28 gallons per flush or less, which EPA describes as 20% less than the federal standard of 1.6 gallons per flush[1]. For showerheads, EPA notes that standard models use 2.5 gallons per minute while labeled models must use no more than 2.0 gpm[2]. Labeled bathroom faucets and aerators top out at 1.5 gpm, which EPA says can cut a sink's flow by 30% or more from the standard 2.2 gpm[3].
| Fixture | Federal or standard flow | WaterSense ceiling | Where to confirm locally |
|---|---|---|---|
| Toilet | 1.6 gallons per flush | 1.28 gallons per flush | State plumbing or energy code, utility rebate rules |
| Showerhead | 2.5 gpm | 2.0 gpm | State appliance standards, building department |
| Bathroom faucet or aerator | 2.2 gpm | 1.5 gpm | State code, green building spec on the job |
| Older toilets in the field | Up to 6 gallons per flush | Replacement candidate | Rebate program eligibility list |
Source: U.S. Environmental Protection Agency, WaterSense, 2026[1]
Show the data
| Item | Value |
|---|---|
| Older inefficient toilet | 6 gallons |
| Federal standard | 1.6 gallons |
| WaterSense ceiling | 1.28 gallons |
What the WaterSense label actually certifies
EPA says products and services with the WaterSense label are certified to use at least 20% less water[4]. The label also covers performance, which is the part customers care about: a labeled toilet has been tested to clear waste, and a labeled showerhead has to deliver a usable spray, not just a trickle. When a customer worries that a low-flow toilet means double flushing, the label is your answer.
- Check the label on the box and the product listing, not the marketing copy.
- Keep the model number on the invoice; rebate programs ask for it.
- Do not describe an unlabeled product as WaterSense, even if its flow rate matches.
- If a spec calls for labeled products, photograph the labels before the drywall goes up.
The label is also a useful filter when you stock the van. Carrying one labeled toilet line, one labeled showerhead family and a box of labeled aerators covers most service calls in any state, because a product that meets the label generally meets the stricter state limits as well. Check that assumption against your own state's list once a year, since a few jurisdictions set limits on product categories the label does not address.
State and local limits: how to check in ten minutes
Several states, California among them, have adopted fixture limits tighter than the federal baseline, and some water utilities in dry regions add their own retrofit requirements at sale or remodel. The rules change, so build a short check into estimating rather than relying on memory.
Find the governing code
Identify the plumbing code edition your jurisdiction adopted and any state appliance efficiency rules that apply to fixtures.
Check the utility
Look for retrofit-on-resale rules and current rebate programs on the water utility's site; save a dated copy.
Check the job documents
Public, multifamily and green-certified projects often require labeled fixtures regardless of local code.
Record the decision
Note the limit you applied and its source on the estimate so the installing crew and inspector see the same thing.
When the customer wants more flow
Some callers ask for a high-flow showerhead or for the restrictor to be removed. On a permitted job in a strict state that is a code question, not a preference, and in any state it is a reputation question if the shop is seen tampering with products. A calm script helps:
Script: We can only install fixtures that meet the code here, so I can't remove the restrictor. What I can do is show you a couple of labeled models that are rated for a stronger spray, and check your water pressure, because low pressure is often the real cause.
That last point is the sales opportunity. Weak showers are often a pressure, scale or valve issue. A pressure test, a cleaned or replaced cartridge, or a new pressure-reducing valve can solve the complaint without breaking any rule.
Turning efficiency into a household water story
Efficiency sells better when it is about the customer's bills than about regulation. EPA says toilets account for nearly 30% of an average home's indoor water use, and that replacing old toilets with labeled models can save a family nearly 13,000 gallons and more than 170 dollars a year[1]. Across a whole house, EPA estimates a family can save more than 380 dollars a year by retrofitting with labeled fixtures[5].
Nearly 30%
Share of indoor home water use that goes to toilets[1]
Showering accounts for nearly 17% of residential indoor water use, according to EPA, and a labeled showerhead can save the average family 2,700 gallons a year[2]. Those two fixtures are the obvious bundle for a bathroom service visit.
Multifamily, commercial and public jobs
On larger jobs the fixture schedule is usually decided before you see the drawings. Architects write labeled products into the specification for green building programs, public owners write them into bid documents, and property managers ask for them because tenants pay water bills in some buildings and owners pay in others. Read the fixture schedule line by line during estimating; a substitution request after award is slower and riskier than a question during the bid.
- Ask whether the spec allows equal products or names a single manufacturer.
- Confirm whether urinals, flushometer valves and pre-rinse spray valves in kitchens are in scope, since each has its own efficiency rules.
- Price the submittal work: cut sheets with the label shown, model numbers and flow ratings.
- On occupied buildings, plan replacements unit by unit and tell residents what will change.
Rebate paperwork that customers actually finish
Utility rebates fail more often on paperwork than on eligibility. The customer has to claim most rebates, so the shop's job is to make that easy without promising the outcome.
- Hand over an invoice that lists each fixture's brand, model number and the words WaterSense labeled where true.
- Note what was removed, since many programs require proof that an older fixture was replaced.
- Include the install address and date exactly as they appear on the water bill.
- Add the program's link or name on the invoice and tell the customer the claim deadline you saw.
Example: a two-bath remodel quote
Example (fictional): a homeowner calls about a running toilet in a house built in the late 1980s. The technician finds two original toilets stamped 3.5 gallons per flush, standard showerheads and old aerators. The quote offers three options: repair the flapper only, replace both toilets with labeled models, or do both bathrooms with toilets, showerheads and aerators. The shop prints the utility's current rebate page with the date on it, lists rebates as estimates for the customer to claim, and records the code limit it applied for the inspector. The homeowner picks the middle option and books the showerheads for a later visit.
Common mistakes to avoid
- Quoting from a product box without checking the state limit for the job address.
- Promising a rebate amount instead of pointing the customer to the program terms.
- Mixing labeled and unlabeled fixtures on a job whose spec requires the label.
- Leaving model numbers off invoices, which blocks rebate claims later.
- Treating a weak-shower complaint as a fixture sale before testing pressure.
Fixture rules sit alongside other efficiency rules your team should know, including the heat pump water heater install checks and the restrictions covered in drought and water restrictions for plumbers. Keep the paperwork too; the record retention guide covers how long.
Frequently asked questions
Is WaterSense required by law?
No. WaterSense is a voluntary EPA label. Federal and state limits are the legal requirements, but many rebate programs and project specs require labeled products.
What is the federal limit for toilets?
The federal standard is 1.6 gallons per flush. WaterSense toilets use 1.28 gallons per flush or less.
Can I remove a showerhead flow restrictor if the customer asks?
Avoid it. On a permitted job it can break code, and it exposes the shop. Test water pressure and offer labeled models with a stronger spray instead.
How do I know if my state has tighter limits?
Check your state plumbing and appliance efficiency rules and your water utility's site, then record the limit you applied on the estimate.
References
U.S. Environmental Protection Agency, WaterSense (2026). Residential Toilets (opens in a new tab) β
U.S. Environmental Protection Agency, WaterSense (2026). Showerheads (opens in a new tab) β
U.S. Environmental Protection Agency, WaterSense (2026). Bathroom Faucets (opens in a new tab) β
U.S. Environmental Protection Agency, WaterSense (2026). About WaterSense (opens in a new tab) β
U.S. Environmental Protection Agency, WaterSense (2026). Statistics and Facts (opens in a new tab) β