Key takeaways
- Run the visit in a fixed order so every technician covers the same ground in about the same time.
- Start with a meter test: it catches hidden leaks before you open a single cabinet.
- Toilets use nearly 30% of indoor water[1], so flappers, fill valves and silent leaks deserve a line of their own.
- Record ages, readings and photos, not just pass or fail; next year's visit and any replacement talk depend on them.
Why the checklist matters more than the visit
A member visit that depends on which technician shows up is not a product. The checklist turns the yearly inspection into something the member can predict and the office can schedule. It also produces the findings report that makes members renew, because a report full of specific readings shows the visit was real work.
Keep the checklist to what a technician can do well in about an hour in an average house. Anything that needs a second visit, such as a camera inspection or a repair, becomes a recommendation with its own estimate, not an add-on squeezed into the inspection.
The visit sequence
Meter test on arrival
Ask the member not to run water for a few minutes, read the meter or watch the leak indicator, and note any movement. Do it first, before your own testing uses water.
Main shutoff and pressure
Locate and exercise the main shutoff, label it, and measure static pressure with a gauge at a hose bib or laundry connection.
Water heater
Record type, fuel, age, setpoint and condition; test the relief valve if your policy allows and check the area for moisture.
Room by room
Kitchen, bathrooms, laundry and utility areas: supplies, stops, traps, fixtures, toilets and visible drain lines.
Outside and unheated spaces
Hose bibs, irrigation connections, crawl spaces, garages and any pipe in an exterior wall.
Report before you leave
Walk the member through findings in priority order and send the written report the same day.
The checklist by area
| Area | Check | Record |
|---|---|---|
| Whole house | Meter or leak indicator with all fixtures off | Movement yes/no, reading, time observed |
| Main shutoff | Operates fully; handle and packing condition | Location photo, valve type, any weeping |
| Pressure | Static pressure at a hose bib; pressure-reducing valve if fitted | Reading in psi, regulator age and setting |
| Water heater | Age, venting, relief valve and discharge line, sediment, leaks, expansion tank | Serial or install date, setpoint, photos |
| Toilets | Flapper seal, fill valve, flush, base, supply line | Dye-test result, flapper age where known |
| Faucets and showers | Drips, cartridge wear, aerators, diverters | Fixtures dripping and estimated rate |
| Under sinks | Supply lines, stops, traps, disposal, dishwasher connection | Line material, stop condition, moisture |
| Drains | Flow at each fixture, cleanout access, odors | Slow fixtures and any recurring clogs |
| Outdoor and unheated spaces | Hose bibs, irrigation backflow, insulation on exposed pipe | Freeze risks, missing insulation |
The record column is what makes the visit useful a year later. A note that the water heater was installed in a given year, set to a given temperature and showed light sediment lets next year's technician see change rather than starting over.
Leaks: start with the numbers
EPA notes that a family of four using more than 12,000 gallons a month probably has a serious leak, and that 9% of homes have leaks wasting 50 gallons or more a day[2]. Ask the member for a recent water bill before the visit; a usage figure out of line with the household size tells the technician where to spend time.
Toilets account for nearly 30% of an average home's indoor water use[1], so a silent toilet leak is one of the most common findings. Use dye tablets in each tank and check the flapper. EPA advises checking flappers periodically and replacing them at least every five years[2], which gives the report a clear, dated recommendation.
- Toilets 30%
Source: U.S. Environmental Protection Agency (WaterSense), 2026[1]
Show the data
| Item | Value |
|---|---|
| Toilets | 30% |
Water heater: age is the headline
Traditional tank water heaters have an expected life of about 10 to 15 years, against more than 20 years for tankless units, according to a Department of Energy Building America guide[3]. Record the age from the serial number or install sticker, because it drives every later conversation about repair or replacement.
- Look for rust at fittings, moisture under the tank and water in the drain pan.
- Confirm the relief valve discharge line is present, the right size and ends where your local code requires.
- On gas units, look at the venting and draft hood for signs of spillage; if anything looks wrong, stop and follow your gas safety procedure.
- Drain a little water from the valve to judge sediment; schedule a full flush if needed.
- Note the setpoint. CDC says Legionella grows in building water systems at 77 to 113 F[4], so stored water should not sit in that range; protect against scalding with a mixing valve where one is needed.
Pressure, valves and supply lines
Static pressure is one of the few readings that tells you about the whole system at once. Measure it at the same point every year, with no fixtures running, and write the number down. High pressure strains supply lines, fill valves and water heater relief valves; a reading above the limit in your local code is a reason to recommend or service a pressure-reducing valve. A reading that jumps after the water heater runs suggests thermal expansion, so check for an expansion tank where one is required.
Exercise every shutoff the member would need in an emergency: the main, the water heater cold supply and the fixture stops under sinks and behind toilets. Old multi-turn stops often seize or start weeping after they are moved, so tell the member before you turn them and carry replacements. Note the supply line material at each fixture. Braided lines past their manufacturer's service life and old plastic or rubber lines are the kind of finding that goes on the plan-for list with a date.
Drains and fixtures
Run water at each fixture long enough to see how it drains and listen for gurgling, which can point to venting problems. A single slow fixture is usually a local clog; several slow fixtures on the lowest level, or a history of backups, point to the main line and justify a separate camera inspection. Check that cleanouts are reachable and not buried under landscaping or stored boxes, because the member will need them in an emergency.
For faucets and showers, look for drips, worn cartridges, mineral build-up on aerators and diverters that leak while the shower runs. Record what you find even when it is minor. A slow drip that is a watch item this year becomes a fix-now item next year, and the report should show that history.
Freeze risks and outdoor lines
The fall visit is the one to check freeze exposure. The American Red Cross lists the pipes that freeze most often: those exposed to severe cold, such as hose bibs and sprinkler lines, and those in unheated interior spaces such as basements, crawl spaces, attics and garages, or along exterior walls with little insulation[5]. Mark each on the report with a fix: insulation, a frost-free sillcock or a shutoff and drain point.
Members who travel in winter should hear the Red Cross advice to leave the heat set no lower than 55 F while away[5]. It is a simple tip, and members remember the company that gave it to them.
The findings report
- Fix now: anything leaking, unsafe or likely to cause damage soon, with a price on the spot.
- Plan for: worn parts and aging equipment, with an estimated timeframe and a written estimate.
- Watch: items that are fine today but worth a second look next year.
- All good: the list of what was checked and passed, so the member sees the whole visit.
Attach photos to every fix-now and plan-for item. Keep wording factual. The report is not a sales document, and members can tell when it reads like one; selling without being pushy covers how to keep it that way.
Example: a 60-minute member visit
Example (fictional): the technician finds the meter indicator moving with every fixture off. The dye test shows the upstairs toilet leaking through its flapper, which is replaced on the spot. The water heater is 11 years old with moderate sediment and a dry pan; it goes on the plan-for list with a replacement estimate. One hose bib on the north wall has no frost protection and goes on the fix-now list before winter. The report lists 22 items checked, two fixed, one planned and one to watch.
That report does three jobs: it shows the member the value of the plan, it gives the office a scheduled follow-up, and it gives next year's technician a baseline. Pair it with a planned water heater flush visit for members whose tanks need more attention.
Training technicians to use it
Build the checklist into the field app so it cannot be skipped, with required fields for the readings that matter: meter result, pressure, water heater age and setpoint. Optional fields invite blank reports. Have new technicians shadow two member visits before running their own, and review the first five reports each technician files for missing photos or vague notes such as โlooks OK.โ
Once a quarter, compare reports across technicians. If one tech finds far fewer issues than the others in similar houses, ride along before drawing conclusions; if one finds far more, check that the findings are real and documented. The aim is consistency, so that a member gets the same visit whoever arrives.
Frequently asked questions
How long should an annual plumbing inspection take?
Plan for about an hour in an average single-family house. Larger homes, multiple water heaters or well systems need more time, so price and schedule those visits separately.
Should the inspection include a sewer camera?
Usually not as standard. Recommend a camera inspection when the technician sees recurring clogs, slow drains throughout the house or an older clay or cast-iron line, and quote it as its own job.
What season is best for the annual visit?
Fall works well because it lets you check freeze risks before winter, but spread visits across the shoulder months so they do not compete with peak emergency work.
Should technicians test the water heater relief valve?
Set a company policy. Testing confirms the valve opens, but old valves sometimes fail to reseat, so technicians should be ready to replace one and should tell the member first.
References
U.S. Environmental Protection Agency (WaterSense) (2026). Residential Toilets (opens in a new tab) โ
U.S. Environmental Protection Agency (WaterSense) (2026). Fix a Leak Week (opens in a new tab) โ
U.S. Department of Energy, Building America (Consortium for Advanced Residential Buildings) (2009). Tankless Water Heaters (Building America guide) (opens in a new tab) โ
Centers for Disease Control and Prevention (2026). Causes and How Legionella Spreads (opens in a new tab) โ
American Red Cross (2026). Frozen Pipes (opens in a new tab) โ